PowerFilm Version  5.5.2 - Release Notes
========================================

Availability: June 2010

1. Support for Windows 7 added.  New USB ASPI driver for Windows 7 (Kmaspi32.dll).
2. Windows manifests embedded.
3. New high resolution application icon added.
4. References added to new '3000 DV Plus' and '2400 DV Plus' scanners.
5. Users are now able to choose to email scanned images as PDF files.
6. Fix added to clipboard copy function so that only the selected area was copied to the clipboard.  This was also affecting the 'Keep Selected' function.


The v5.5.2 installation program will upgrade an existing v5.5 system.


PowerFilm Version  5.5.1 - Release Notes
========================================

Availability: July 2009

1. Selected area printing now working correctly.
2. Additional detailed logging available by putting /level 6 on the command line ("/level<space>6").
3. Support for new style Mini MARS II controller (any unit with serial number greater than 81007060).
4. Point size of text annotations is now relative to the resolution of the image and the default is 12 `point.  Previously the default was 24 point but on a 600 dpi image, it looked tiny because the resolution was not being taken into account.  We also added reg settings in HKLM where we can read alternative default font details from.  HKLM\Software\InfoCAP Technologies\Imaging\

Annotation Font (Arial)
Annotation Size (12)
Annotation Bold (True / False)
Annotation Italic (True / False)

5. After cut, image does not jump up to top/left.
6. New PowerLicence that addressed a problem in France where some of the abbreviations for short date months were more than 3 chars.  e.g.  Janz.  When PowerFilm started, the user received the message "failed to connect to licence server".

The v5.5.1 installation program will upgrade an existing v5.5 system.


PowerFilm Version  5.5 - Release Notes
======================================

Availability: Sept 2008

Enhancements:

1. Support for the DSV-E USB interface.  An option has been added to the 'Settings' tab in the 'Options' dialog to allow the user to define whether PowerFilm should use the PC's USB or SCSI bus to communicate with the scanner.  The default is USB. Note that the SCSI interface is not supported under Windows Vista as Microsoft have withdrawn support for WinASPI.  Note that in USB mode, the scanners MUST be set to identify themselves as MINOLTA devices (ob set to d0).

2. PowerFilm is now supported under the Business Edition of Windows Vista.  Note that under Windows Vista, if UAC is enabled and the user is not logged on as an Administrator level account, they are prompted for Administrator credentials before they are able to continue with the installation.

3. The PowerFilm default batch path is now "..\Documents and Settings\All Users\Application Data\PowerFilm Data". Note that the 'Application Data' folder resolves to 'ProgramData' under Windows Vista (usually "C:\ProgramData").  Also note that PowerFilm log files are also written to a 'Logs' folder under this path.

4. The PowerFilm 5.5 installation program checks for the presence of KMASPI32.exe (v2.0.0.1) in the Windows system32 folder.  If this file does not exist, the 'KM MS7000/6000 MKII ASPI Driver' installation program is launched. This is the installation program of the WinASPI emululator for the USB bus.

5. The PowerFilm 5.5 installation program automatically opens security access to 'HKLM\Software\InfoCAP Technologies Ltd' in the Windows registry to all users. So this should no longer be a requirement to do this manually if the customer wants to run as a non-Administrator account. 

6. The MARS controller Com Port selection on the 'Controller' tab of the 'Options' dialog has been changed to a drop down pick list (Com Ports 1-20).  This was done to provide support for USB to Serial interface kits.  On some PC's the USB to Serial kit loads as a high Com Port number.

7. Latest clock tampering PLF code added to the licensing software.

8. A slightly newer version of WinASPI is available on the installation CD (4.7.1.2).  Note that the PowerFilm setup program does not install WinASPI.

9. Note that after closing PowerFilm, the USB driver takes about 15 to 20 seconds to unload from memory.  If the user attempts to restart PowerFilm during this period, they will receive a message saying that PowerFilm is already running.

10. Note that xs3000.dll will now register during the PowerFilm installation process even if WinASPI (SCSI) or the USB driver is not installed.

11. Supported operating systems are now Windows 2000 (SP4), Windows XP Pro (min SP2), Windows 2003, Windows Vista Business Edition.  Latest service packs should be loaded.

12. To upgrade to v5.5 from previous versions of PowerFilm, you should completely uninstall the previous version, and ensure that you delete the PowerFilm folder from under the 'Program files' structure before installing v5.5.  Note that this supersedes the note in an earlier version of these release notes that advised that you can install v5.5 over the top of previous versions of the software.  Ensure all suspended batches are processed before upgrading.  Note that a new licence will be required.

13. Any new messages, menus and button names that are not translated in the local.ini files are detailed in the file 'New Local strings not translated in 5.5.ini' which can be found in the '..\PowerFilm Data\PowerFilm Local Files' folder.  Once translated, they can be added to the appropriate local.ini file.

14. The 'Batch Save' function has been rewritten to make it more robust and resilient to errors during the 'Save' process.  If a crash occurs during the Save process, when PowerFilm detects this as the program is restarted, the user will receive the normal message indicating that an In Progress batch has been detected.  It then asks if the user would like to recover the batch.  If they answer Yes, they will receive a further message indicating that the suspended batch was in the process of being saved and that the Save process will be continued.  PowerFilm will then attempt to re-save the entire batch.  The Batch Save function now creates; renumbered TIFFs, multipage TIFFs, PDFs, etc, in a temp folder at the same level as the batch folder (i.e. 00000001_temp).  When the Save process completes successfully, the original batch folder is deleted and the temp folder renamed as the batch folder.
In addition, PowerFilm now writes the .sus file to the batch folder when a batch is suspended along with a binary registry backup file.  Note that it is important that the user answers Yes when prompted to recover a batch.  If they answer No, the temp folders will be left in the state they were in at the point of crash.  If the user does answer No, PowerFilm will still write the .sus file and the binary registry backup file to the batch folder.  This means that the batch could be manually recovered later by opening the .sus file from the batch folder.  Note that this is not normal operation and is intended as a method for batch recover that may be adopted under guidance from support personnel.


PowerFilm Version  5.4 - Release Notes
========================================

Availability: Aug 2005.

Enhancements:

1. Customisable User Interface functionality added.

2. New Batch Load option for loading a batch of TIFF images without idx or cfg files.

3. Kofax Ascent Form Type Support added.


Fixes:

1. Kofax Ascent upload failed in Renumber was not enabled in the Output section of the batch tab.

2. Registry updated modified to add to existing new key rather than overwrite it.

3. Licence now checked as soon as the application starts.  Previously, if an error occured during initial startup, a licence would not be requested and the application would start without a licence.  An error indicating that the program could not connect to the licence server would then be displayed 30 seconds later.


PowerFilm Version  5.3 - Release Notes
========================================

Availability: May 2004.

Enhancements:

1. Licensing software replaced (Crypkey removed).  Program startup is faster and licensing issues alleviated.  If the auto 14 day licence is not activated because the installing user does not have registry access to HKLM, re-installing the software with the correct privileges will activate the 14 day licence.  Full details of the new licensing procedures can be found in the 5.3 document addendum.

2. New image control implemented for viewing, printing, saving images.  Windows Imaging component is no longer required.  Images are now centered in the viewer.

3. Users can now print with/without annotations.  If annotations are displayed, they will be printed.  Show/Hide annotations is under the Annotations menu.

4. Save as PDF can now include/exclude annotations.  If annotations are displayed, they will be burnt into the image before PDF conversion.

5. Images are no longer initially saved as temp files.  Saving batches is faster.

6. PDF output is now standard in the software (previously an option).

7. Image branding version introduced for demo/evaluation purposes.

Notes:

1. New annotation tool bar does not include; Text from file, Rubber Stamp, Hyperlink, Initials stamp.

2. Greyscale images are converted to bitonal when converted to PDF.  When saving PDF and Tif, TIFF may now be saved with JPEG compression.

3. Print selected area does not print annotations.

4. Print output is controlled by the 'Save As' setting on the Image tab.  Scan a greyscale image then change 'Save As' to black and white (bitonal) then print, will print a bitonal image.

5. Rescan cannot be instigated again until the current rescan process is complete.

6. Images are now centered on the page when printed with 'Fit to page'.


PowerFilm Version  5.2.1 - Release Notes
========================================

Availability: September 2003.  This release will be available as a downloadable upgrade to 5.2 and will become part of the shipping release in 5.3.

Intermediate release to add the following enhancements and fixes:

Enhancements:

1.New menu option under the Action menu, 'Merge with previous page'.  When more than one image has been scanned, this option merges the currently selected image underneath the previous image.  The second image is then discarded.

This feature is especially useful on the 2400 DSV scanner.  With the 2400DSV, the standard 'Custom Duplex (Merge)' functionality may result in a low definition merged image because the user needs to zoom out to a high degree to fit front and back images into the scanner display screen at the same time.  The 'Merge with previous page' functionality allows the user to scan the front image fully zoomed in to obtain maximum image definition, then scan the back image, then merge the two together.  The result is a high definition merged image.

2. It is now possible to set a Application Startup Password.  On the 'Password' tab of the PowerFilm Options dialog, enter the Supervisors password and check the 'Password required for Application start' check box, then enter the required password.

3. The status bar now indicates the size of the scanned image (in Kb) along with the image file name.

Fixes:

1.When an image area is 'rubber banded' and then Print is selected, the 'Selected Area' checkbox is enabled on the print options dialog and the selected area is printed.  When a subsequent image is scanned and print is selected, the 'Selected Area' is still checked in the print dialog.  This results in a blank image being printed as there is no rubber banded area defined.  Now fixed.

2. When multiple images are being displayed (2,4 or 6), after choosing to print a selected area of the image, attempting to print the whole of a subsequently scanned image results in the message 'No annotation mark has been selected - unable to copy the image data to the clip board, using Print'.  Now fixed.

3. Cut / Copy / Keep Selected should only be enabled if there is a rubber banded area defined.  At startup the Cut and Copy buttons (but not menus) were enabled. Now fixed.
 
4. Cut and copy now disabled when we scan the next image or click on another viewer in multi viewer mode.

5. Japanese version now uses "~~~" in transaction log.

6. The Options tab showed all config frames when no scanner was detected.

7. Custom Duplex and Custom Duplex (Merge), on 2400D only, did not scan true grey scale images.

8. Log file indicated that scanner was not attached when it was.


Notes:

1. New entries for localisation files:

[MESSAGE]
Start Password=Enter password to start
  
[OPTIONS]
Please Enter Application=Please Enter Application1
Confirm Application=Confirm Application1
Password required for application start=Password required for application start1

2. PowerFilm only updates the registry during printing when the user changes the target printer or the Output Options (inch to inch, etc).  Previously, the registry was updated for each print job.  This was done to address the problem of PowerFilm "disapearing" intermittently after a print job was started.  If the printer sent a status update at the exact moment that PowerFilm was updating the registry, a Windows exception occurred.


PowerFilm Version  5.2 - Release Notes
========================================

1. Changed default install folder to ...\Program files\KODAK.

2. Changed default program group to KODAK

3. New license software version 6 added.  Note that a new site key will be required.

4. Users are now able to choose to INSERT pages into a batch rather than APPEND pages to the end of the batch.  New menu items (Append Pages/Insert Pages have been added to the Action menu.  The default in still APPEND.  PowerFilm will revert to APPEND when the program is restarted.

5. A new choice of 'Show 2 Viewers' has been added to the view menu.  Users may choose to display the two viewers vertically or horizontally (configured on the 'Settings Tab' of the PowerBook Options dialog).

6. The manual 'File/Save Image As' functionality has been enhanced to support the saving of single or multiple images as PDF files as well as single or multipage TIFF files. (Save as PDF requires the PDF option to be installed.)

7. The Suspend Batch feature has been enhanced to attempt a number of retries during the save process.  Previously, if the batch was being suspended to a network drive, the suspend function may have failed if the network connection was unreliable (or potentially in periods of heavy network traffic).  Retries are written to the log file.

If a batch is being saved and an error occurs the operator is prompted to try and suspend a batch.  When this batch is loaded an integrity check is carried out.  The integrity check looks for missing images and if any image is not found it is replaced by ErrorMsg.Tif (or to a file specified in the registry).  Upto 20 images will be replaced before the integrity check will fail.  If the integrity check passes the batch will be left open, if the batch is suspended again and reloaded the integrity check will not be re-run.  If there are any other errors whilst the batch is loaded or the integrity check fails the batch will not be opened.  The log should detail any errors.  The Load Suspend batch process has been modified to write more information to the log file.

8. A new browse dialog has been added to set the output path.  This allows users to define UNC paths as the output path.  Additionally, users may create new folders from this dialog.

9. The view scale to grey functionality now updates all viewers when it is turned on/off.

10. New Image Annotation feature added.

11. In 5.2 we now save the current config info with the suspended batch.  Previously, the state of the config as it was when scanning commenced was saved with the suspended batch.  Now the state of the config when the batch is suspended is saved.

12. In 5.2, we now prompt for users to accept the batch if they try to close PowerFilm.  Previously, we just said cannot exit while a batch is in progress.

13. Duplex Custom and Duplex Custom (Merge) now both use the same coordinates.  Previously, Set Size/Fix Size would need to be run for both Duplex Custom and Duplex Custom (Merge).

14. Height and Width labels on Image tab were inverted for 3000DSV scanner.  Now corrected.

15. Set Size at 800 dpi caused 'unable to set window parameters' on 3000DSV.  Now corrected.

16. Front Panel scanning on DSV scanner caused PowerFilm to get into a loop where field validation fails, e.g. field is required - and a value has not been entered.  PowerFilm no longer gets into a loop but a normal scan (from the PowerFilm interface)is required after validation before front panel scanning can continue.

17. The Reverse Image functionality (Options Tab) is now operational.  This was broken is the previous version.

18. PowerFilm will now recognise Kodak, Minolta and B+H branded digitisers (equivalent supported models)

19. Progress monitor added to status bar, displayed when a large suspended batch is being opened.

PowerFilm Version  5.1 - Release Notes
========================================

Primary reason for Release:

1. Add support for the MARS IV controller. 

Software Effected - All previous PowerFilm versions.

Availabiliy - June 2002

Users are now able to select MARS IV as an alternative to MARS II from the Controller Tab on the PowerFilm Options window (File/Options).  The Film Tab has been updated to reflect the use of Tri Level Film.  In addition, the following film levels may now be selected:

A Channel Single Level
B Channel Single Level
A Channel Dual Level
B Channel Dual Level
A Channel Tri Level
B Channel Tri Level
B Channel Batch - A Channel Item
A Channel Batch - B Channel Item

Note that only the first four levels are available with the MARS II controller.

A 5.1 document addendum discusses the use of the MARS IV controller with PowerFilm version 5.1.

Specific MARS IV Notes:

1. This version of PowerFilm specifically certifies the software for use with the RFC15.  The RFC21 has not yet been fully tested with PowerFilm version 5.1.

2. The firmware revisions for the MARS IV controllers and carriers to work in conjunction with PowerFilm version 5.1 are as follows:

RFC 15        1354-IC1 6033-08 on the main CPU PCB in IC-1. 
MARS IV       1358 IC6A VER 4.6 and 1358 IC43A VER 4.6. 

RFC21         1371-6013-06 in IC-2 position on the PWB-A 
MARS IV       1358 IC6A VER 5.5 and 1358 IC43A VER 5.5 - USA
	      1358 IC6A VER 6.6 and 1358 IC43A VER 6.6 - Europe

3. Intermittently, during scanning, the MARS IV controller may stop responding to the software.  This resulted in the scanning process being terminated prematurely.  To overcome this, PowerFilm will send up to 3 retries to the MARS controller during scanning.  When this occurs, operators may notice a slight delay in the scanning process.  Retries are logged in the PowerFilm log file.


Other Enhancements added in this release:

1. IDX files are now written for the PDF Output type.
2. Batches output as PDF and Tif may now be loaded after Scan/Accept Batch (File/Load Batch).
3. Batches output to Kofax Ascent may now be loaded after Scan/Accept Batch and re-uploaded to Kofax Ascent.
4. Error log updated to include:

-Windows O/S.
-Full Product Version.
-Scanner information as displayed in help.about.
-Define MARS Controller attached.


Fixes:

1. Image auto masking, frame elimination, exposure settings, etc are now correctly applied during re-scan.


Notes:

1. PowerFilm will no longer recognise Minolta branded digitisers.
2. Additional entries have been made in the localisations files (5.1 Local.ini) to support the new functionality.  See 'New for 5.1 Local.ini' in the ..\PowerFilm Local Files foder.
3. The PowerFilm auto license has been extended to 14 days.


PowerFilm Version  5.0.3 - Release Notes
========================================

Primary Reason for Release:

1. Suspend batch fix.

Software Effected - All previous PowerFilm versions.

Availability - January 2002

Fixes:

1. PowerFilm now ensures that all temp file names are unique even after restarting Windows.  Previously, if Windows was restarted, there was a chance that existing files could be overwritten when continuing scanning after opening a suspended batch. All temp files are now given a date and time suffix in the format (dd_mm_hh_mm_ss).


PowerFilm Version  5.0.2 - Release Notes
========================================

Primary Reason for Release:

1. Support for Windows XP added.

Software Effected - All previous PowerFilm versions.

Availability - January 2002

Fixes:

1. PowerFilm now exits gracefully when full access to "HKEY_LOCAL_MACHINE\Software\InfoCAP Technologies" is denied in the Windows registry.

2. PowerFilm no longer exhibits a registry access error when full access to "HKEY_LOCAL_MACHINE\Software\Kofax Image Products" is denied in the Windows registry.  PowerFilm only needs read access to this key and only when the Kofax Ascent option is installed.

3. A small scan delay (100ms) between MARS scans has been removed as it is no longer necessary.

4. Corrupted images are no longer created randomly when Auto Frame Elimination is switched on when scanning with a MARs II controller.

5. PowerFilm now forces a minimum image size of 30mm length or width as defining a scan area smaller than this sometimes caused scan errors.

6. If no scanner is detected at startup, all options are now removed from the 'Options' tab as options are scanner specific.

7. AFE, Automasking and Centering are now switched off when a 'Set Size' scan is performed.


PowerFilm Version  5.0.1 - Release Notes
========================================

Primary Reason for Release - Add support for the following:

1. PowerFilm now supports the new 2400DSV (MS6000) and 3000DSV (MS7000) Scanners.

2. Windows 2000 support added (DSV models only).

3. CDPublish is now included with the PowerFilm software (launched from the PowerFilm File menu).  CDRetrieve is now free for distribution to users.  The installation program for CDRetrieve is included on the PowerFilm install CD.

Software Effected - All previous PowerFilm versions.

Availability - October 2001

Other Enhancements added in this release:

1. Users may choose to display 1, 4 or 6 images at a time during scanning.

2. Support for Greyscale board option for DSV scanners.  PowerFilm will automatically detect the presence of the greyscale board in the scanner and enable 'Greyscale' as a 'Save as' option on the Image tab.  On Windows NT4, users may choose to compress Greyscale images using JPEG compression.  On Windows 2000 users may choose to compress Greyscale images using JPEG or LZW compression.  The presence of a Greyscale board is displayed on the PowerFilm Help.About dialog.

3. The front panel on the DSV models may be used to start scanning and control image sizes and composition.

4. 'Custom Duplex' and 'Custom Duplex (Merge)', previously only available on the 3000DS and 3000DSV models, is now available on the 2400Ds and 2400DSV models.

5. Users may now choose to 'Suspend' batches and then open them later to continue scanning.

6. PowerFilm will now automatically recover a batch after a system crash.  The batch will be restored to the state it was in at the point of the crash.  To implement this feature, PowerFilm no longer closes batch sub folders (renaming temp image files and creating idx/csv/cfg files) during the scanning process with 'batch Subdirs by: count'.  When a batch is accepted, all temp image files are copied to the final TIFF name and only when the batch has been safely saved are the temp files removed.  This means that accepting a batch may take longer for large batches.  Progress is displayed on the status bar as a percentage value during this process.

7. Users may now choose to automatically 'drop out' blank pages from a batch during the scanning process based on a user defined image byte count threshold.

8. The 'Output Options' section of the Batch tab has been updated and extended.  The IDX output type has been renamed as 'CD Publish'.  The 'CD Publish' and 'Comma Delimited' output options are now selected from a pick list.

9. A 'Renumber' check box has been added to the 'Output Options section, to re-number (or resequence) the tiff file numbers when the batch is saved.  This is useful when pages have been deleted from the batch, either manually or due to blank page dropout.

10. PDF output is now available as a cost option.  Users can choose to output PDF only or PDF and TIFF.  When this option is installed, PDF options appear as choices in the output format picklist.

11. Kofax Ascent output is now available as a cost option. Installing this option allows PowerFilm to behave like a Kofax Ascent scan station.  Batches/Documents are automatically uploaded to Ascent when the batch is accepted.  When this option is installed, 'Kofax Ascent' appears as a choice in the output format picklist.

12. Users can now manually save scanned images in an open batch to the Windows file system with names of their own choice.  Individual images or the entire batch may be saved as multi page TIFF files.

13. Image resolution options extended to 800dpi (DSV scanners only).  Note that 800dpi is not available for all Paper sizes on the 3000DSV.  PowerFilm will warn you if you have selected a paper size not supported at 800dpi.

14. Users may now select an area of an image for print or email by drawing a box using the mouse.

15. The requirement for a password to save a modified image has been removed.

16. The 'View' menu can now be accessed by right clicking on an Image.

17. The Windows operating system being used is now displayed on the start up splash screen and the Help.About dialog.

Fixes:

1. Film may now be rewound when a batch is in progress so that a batch may consist of images scanned from many films.

2. Goto page now working as designed.  Previously, entering a page number and pressing ENTER while a batch is in progress would start the next scan.

3. The Batch tab is now disabled while a batch is opened.

4. Index fields are no longer cleared when starting scan on a new batch.

5. Cancelling the 'Delete Configuration' dialog no longer deletes the configuration.


PowerFilm Version 4.2.34 - Release Notes
========================================

Primary reason for release - maintenance.

1. Batch sub folders erroneously being numbered out of sequence - now fixed.

2. Continuous count mode only updating the image number count every other batch folder.  So scanning 2 images into each batch would result in 00000001.tif, 00000002.tif in the first batch folder, the same again in the next batch folder and the 00000003.tif and 00000004.tif in the third batch folder.  Now fixed.

Software effected - PowerFilm version 4.2.30, 4.2.32.

Availability - 2/6/2000


PowerFilm Version 4.2.33 - Release Notes
========================================

Internal Release Only.


PowerFilm Version 4.2.32 - Release Notes
========================================

Primary Reason for Release - Add new "Batch by Subdirs" feature.

1. When "Batch by Subdirs" is set to count, IDX(or CSV) files and CFG files are now automatically written to each sub directory as the file count parameter is reached and the sub directory is closed.  Temporary TIFF files are also given their final names.  Previously only temporary TIFF file names were assigned and IDX(or CSV) and CFG files were not written in each sub directory until the entire scan session was closed.

Software effected - PowerFilm version 4.2.30

Availability - 31/3/2000

Notes:

As IDX(or CSV) files are now written and closed during the scan session, changing index values for images in the batch that reside in "closed" sub directories will have no effect.


PowerFilm Version 4.2.31 - Release Notes
========================================

Internal Release Only.


PowerFilm Version 4.2.30 - Release Notes
========================================

Primary Reason for Release - Add support for the following:

1. Scan to printer functionality added.
2. Multipage TIFF file output may now be configured on the batch tab.
3. Custom paper sizes may now be setup with the mouse using the rubber band technique.
4. New feature added to Merge front and back duplex images into a single image.

*****************************************************************************

These release notes also cover changes to the Duplex custom paper size functionality for the ABR3000D that was not included in the user manual.  These changes also effect the Rescan functionality for Duplex scans.  See the following sections below for details: **

1. Duplex Custom Paper Sizes
2. Duplex Custom (Merge)
3. Using Rescan with a configuration that has been setup with "Duplex Custom" or "Duplex Custom (Merge)

******************************************************************************

Software Effected - All previous PowerFilm versions.

Availability - 7th February 2000

Other Enhancements added in this release:

1. After pressing the Green traffic light, users are now able to instigate subsequent scans by pressing the Enter key as an alternative to F5.

2. In Load batch, users are now able to define carry over fields to speed up the indexing process.  Users can also choose to force the overwrite of any existing index information.  A new section in the "Indexing Setup" screen allows users to define a default field that should receive focus as each image is processed.

3. If a MARS or MRS controller has been configured, users are now able to search for frame and batch addresses of up to 10 characters.  The previous limit was 4 characters.

4. New registry setting added - "Full Screen Moves" default = 2 = number of moves MRS and MARS controller make when in full screen mode.

5. New registry setting "Log Files", defaults to app.path \ app.exename.log but can be set to any path that exists plus filename.  This allows users to define the name and location of the PowerFilm log file.

6. New registry setting "Debug".  Set to 1, writes additional information to the log file regarding scanner settings.  Debug also provides information on the status bar that relate to the time it took to scan an image or a range of images.

7. PowerFilm now supports Unicode characters (such as Chinese) in the index field labels.

8. Users are now able to specify a default index field in indexing setup.  This setting denotes the index field that should automatically get focus after the user has scanned the next image(s) or navigated to the next image.

Fixes:

1. Added support for non UK/US versions of Windows that use a character other than a full stop as the Decimal Symbol.  Previously, this would cause PowerFilm to fail during start up.  The main window dimensions would not be loaded so the interface window would be very small.  New information added to the log file. (24 fix)

2. TIFF G3 now saved in configurations.  Previously, PowerFilm would default back to TIFF G4 each time the configuration was reloaded. (23 fix)

3. "App Description" text removed from initial splash screen and product description displayed properly.

4. Changing composition no longer sets compression back to G4.

5. We now show an error message and close down gracefully if we do not have full access to the PowerFilm section of the Registry.

6. After closing Load batch and then selecting the Index tab intermittently resulted in the existing index fields not being displayed.

7. Rewind and move forward one frame icons now only display when MARS or MRS is configured and detected.

8. Date Fields on the Indexing tab now automatically format to the short or long date mask that has been defined.  E.g. if the user enters "1/1" into a field that has been defined with a Long Date mask, PowerFilm will auto reformat it to " 01 January 2000" when "Tab" is pressed or scanning is started.

9. Duplex scanning no longer results in the error message "Unable to set Window parameters".

10. The installation program will now display a message if it does not have local Administration privileges to install the license service.  Message "Unable to open Service Manager - likely fixed by logging in as a local administrator of this machine - reason access denied".

11. Main paper sizes for the ABR3000D are now correctly positioned starting from the top left position on the viewing screen.  2400D images remain centered.

12. In custom paper size setup, the "Length" property box has been renamed to "Height" to more accurately reflect custom paper sizes as viewed on the display screen.

13. When the "Film" Control Tab is enabled, and the user presses the "Setup Film" button, the configuration menu is now correctly disabled (until the user presses "Rewind").  Previously the Configuration menu was left enabled which would allow users to change to an alternative configuration after the film was setup.  Loading a new configuration after the film has been loaded is not allowed as incompatible Film parameters may be inadvertently loaded.

14. If you attempt a rescan when in Duplex mode, we correctly display the message "Rescan not available in this scan mode" but when you OK this message previously an error message; "File not found - unable to display image using RescanImage" was displayed.  This is now fixed.

15. The software has been modified to support additional firmware revisions on the 2400D.  Originally on version 01-0 firmware, all images were centred and the 2400D ignored the Top and Left co-ordinates.  From firmware revision 03-0, Top and Left co-ordinates are now recognised.  This version of PowerFilm will continue to centre images on 2400D's fitted with 01-0 firmware and will also allow users to define image areas offset from the centre of the viewing screen on 2400D's fitted with firmware revisions 03-0 or above.

Notes
=====

1. Images deleted from batches after they have been opened using "Load Batch" are removed immediately from the batch.  If the user then rejects the batch, any changes they might have made to the indexes are discarded but the images are not reinstated.  This means that an error will occur if the batch is re-opened.

2. If you press scan whilst in the middle of setting paper sizes then the scan will occur but it may not be at the settings as displayed in the property boxes.  The displayed values will only be saved once the Set Size button is pressed.

3. On the Batch tab, "Multi Page per Doc Boundary" is only available if a controller is found.  Note this will default back to Single Page if no controller is found.  Also note that the setting of single may be saved back to the configuration which may not be correct.

4. After the "Setup film" button is pressed, the Configuration menu is correctly disabled.  Load a batch and then close it and the config menu is incorrectly enabled again.  This is a known problem and will be addressed in the next release.

5.  Note that creating multipage TIFF files is a very CPU intensive process which can take a significant amount of time to complete.  Multipage TIFF files are created at the point the batch is closed.  If you experience an unacceptable delay here then you may need to reduce the maximum number of pages allowed in each multipage TIFF file (from the Batch Tab).

Duplex Custom Paper Sizes
=========================

Additional functionality has been added to Duplex custom paper size setup that is not documented in the user manual.

The user manual indicates that it is not possible to define different custom paper sizes and orientations for the front and back images using the "Duplex Custom" configuration.  Version 4.2.30 actually allows users to select "Custom Back" as well as "Custom Front" in the image size pick list.  Custom paper sizes and orientations for the front and the back images can therefore be setup independently (given the following restriction) using the rubber band method.

RESTRICTION NOTE - THE ABR3000D CANNOT ACCEPT DIFFERENT HEIGHT AND WIDTH SIZES FOR THE FRONT AND BACK IMAGES, THEREFORE POWERFILM WILL APPLY THE HEIGHT AND WIDTH PARAMETERS SETUP FOR THE FRONT IMAGE TO THE BACK IMAGE.  THIS ALLOWS USERS TO APPLY DIFFERENT TOP AND LEFT COORDINATES TO EACH IMAGE TO DEAL WITH SMALL ALIGNMENT AND SKEW DIFFERENCES BETWEEN THE FRONT AND BACK IMAGES ON THE FILM. USERS SHOULD ENSURE THAT THEY RUBBER BAND A BIG ENOUGH AREA AROUND THE FRONT IMAGE TO DEAL WITH THE EXPECTED SKEW ON THE BACK IMAGE.  AUTO MASKING MAY THEN BE USED TO MASK THE BLACK BORDERS.

To configure the image sizes and orientation for Custom Duplex paper sizes:

Ensure that the front image is aligned in the left portion of the ABR3000D viewing screen and that the back image is aligned in the right portion.

1. Select "Duplex Custom" as the Image Mode Configuration.
2. Select Custom Front.
3. Press Set Size. The max scan area for the left portion of the screen is scanned.
4. Rubber band the area for the Front image.
5. Press Fix Size.  The new scan size is displayed.
6. Select the desired orientation for the Front image.
7. Select Custom Back.
8. Press Set Size.  The max scan area for the right portion of the screen is scanned.
9. Rubber band the area for the Back image.
10. Press Set Size.  The new scan size is displayed.
11. Select the desired orientation for the Back image.
12. Save the configuration if appropriate.
13. Begin scanning as normal.

If you have defined TOP and LEFT coordinates for the back image that would cause the WIDTH and HEIGHT of the image (setup in Custom Front) to exceed the maximum scan area for the back image, you will receive an error message (when you attempt to begin normal scanning) indicating that the front and back image sizes are incompatible.  If this occurs, reconfigure your Custom Front and Custom Back image sizes appropriately.

Duplex Custom (Merge)
=====================

Duplex Custom (Merge) is a new feature added in this release.  Setup for custom image sizes is the same as for "Duplex Custom" above.  However, instead of creating two images (front and back) as each frame is scanned, PowerFilm will Merge the front and back images into a single image.  The left image (as displayed in the ABR3000D viewer) will appear above the right image.  PowerFilm will insert a small amount of white space between the images.  The amount of white space inserted should be sufficient for most requirements, but is also controllable by the registry setting - "Merge Gap".  Note that merging images together is a very CPU intensive process and may take some time for large image areas especially at image resolutions higher than 200 dpi. 

Using Rescan with a configuration that has been setup with "Duplex Custom" or "Duplex Custom (Merge)
====================================================================================================

The Rescan function scans a single image over a previously scanned image currently displayed in the PowerFilm image viewer.  When the Rescan button is pressed when the configuration type is set to "Duplex Custom", the factor that determines if the front or the back image is Rescanned is the "Image Size" choice.  If the "Image Size" is set to "Custom Front", then the custom image size setup for the left portion of the ABR3000D viewing screen is rescanned over the currently displayed image.  If the "Image Size" is set to "Custom Back", then the custom image size setup for the right portion of the ABR3000D viewing screen is rescanned over the currently displayed image.

When the Rescan button is pressed when the configuration type is "Duplex Custom (Merge), both the front and back images are rescanned again and merged together to overwrite the currently displayed merged image.


PowerFilm Version 4.2.21 - Release Notes
========================================

Primary Reason for Release - Support for the Bell + Howell 2400D

Software Effected - PowerFilm version 4.2.10 and 4.2.13 and 4.2.14 and 4.2.15

Availability - 1st February 1999

Other Enhancements added in this release:

1. PowerFilm will automatically detect if the Scanner type is ABR3000 or 2400D

2. Rescan button now available on main button bar.

3. Compression automatically defaults back to G4 when moving from 16 or 256 Greyscale back to Black and White.

4. Cut and Paste and Keep Selected now under password control.

5. Configurations now sorted alphabetically.

6. Additional Status bar messages indicating scanning complete after a range scan.

7. Non fatal SCSI errors may now be ignored and user may choose to automatically ignore future errors of the same type.

8. Cancel button added to the initial Serial Number dialog box.  To allow users to exit without error.

9. Splash screen added to indicate that PowerFilm is loading.

10. TIFF files now written with temp file name in the destination folder (not in the User Interface).

11. About  under the Help menu  now reports the scanner type as detected on the SCSI Bus.

Fixes:

1. Configuration menu now disabled whenever appropriate.  i.e. after Setup Film pressed on the Film Control Tab.  This is appropriate as changes to the configuration may effect parameters that have been set on the Film Control Tab.

2. After Load Batch, Configuration and Action menus now disabled.  Rewind, Save Configuration, and Move Next buttons removed.

3. Can no longer start multiple instances of PowerFilm.

4. Can no longer close PowerFilm while the application is minimised.  Previously this caused PowerFilm to lock up.

5. Configurations may now be deleted and recreated without error.  Previously after deleting earlier configurations, sometimes new configurations could not be created. (21 fix)

6. On the Batch Control Tab, Tiff Start Count will now only accept numeric values. (21 fix)

7. Log files now maintained correctly.  Previously the log files grew without restriction.  Now two days log information is maintained as designed. (21 fix)

8. Keep Selected area is now saved correctly.

Notes:

All PowerFilm Serial Numbers now begin with F.

Documentation Updates:

1. PowerFilm 2400D specific functionality.

The Bell + Howell 2400D Microfilm Digitiser is now supported with PowerFilm version 4.2.21.  Although functionally very similar to the ABR3000D, the maximum scanning area for the 2400D is 300mm x 300mm which accommodates an A4 scan in either Portrait or Landscape orientations.
When driving the 2400D, PowerFilm will also support the implementation of the Mini MARS II controller for single and dual level film with the same functionality as with the ABR3000D.
The 2400D will automatically be detected as PowerFilm starts and certain User Interface functionality will be adjusted to support the features of the scanner.
When the 2400D is detected the following PowerFilm functionality is effected.

About - under the Help Menu - Now reports High Performance Digital Image Processing for the 2400D.

Image Control Tab - Image Mode  Configuration.

Only Centre Scan Mode and Full Screen Mode are available. 

The 2400D does not support Duplex or Cheque Film scanning modes.

All scans are centred on the 2400D display.  Full Screen Mode scans the largest possible image, 300mm x 300mm)

Image Mode - Image Size.

Sizes above A4 (or above 300mm x 300mm using Custom Image Sizes) are not available.

When choosing custom sizes it is not possible to apply values to the Top and Left properties as all image sizes are centred on the 2400D viewing screen.  The Top and Left property boxes are therefore disabled.

Options Control Tab - Options Deskew

The Deskew function  (if the Deskew option is fitted to the scanner) behaves the same as for the ABR3000D

Options  Auto Focus

The Auto Focus option is not available for the 2400D and will remain disabled at all times in PowerFilm.

All other PowerFilm functionality behaves the same as for the ABR3000D.

2. Additional Rescan functionality.

While a batch is still open, PowerFilm allows you to rescan a new image over the top of a previously scanned image.

To rescan an Image:

1. Position the PowerFilm image viewer on the image in the batch that you wish to rescan.
2. Use the Navigation controls on the Film Tab to move to the image you wish to rescan.
3. Press the Rescan button on the button bar. 
4. The new image is scanned over the old image and replaces it in the batch.

Rescanning with Duplex Film (ABR3000D only)

Rescanning with Duplex Film works the same way as for Simplex film except that you need to specify whether you want to rescan the front or the back image.

1. As the previously scanned front and back images are already stored in the batch as separate images you are able to position the PowerFilm image viewer on either the front or the back image that is to be rescanned.
2. Use the Navigation controls on the Film Tab to move to the image you wish to rescan.  Select Left Scan mode or Right Scan mode to scan the front or back image as required.
3. Press the Rescan button.
4. The new front or back image is scanned over the old image and replaces it in the batch.


PowerFilm Version 4.2.15 - Release Notes
========================================

Primary Reason for Release - Fixes to version 4.2.14

Software Effected - PowerFilm version 4.2.10 and 4.2.13 and 4.2.14

Availability - 1st December 1998

Fixes:

1. PowerFilm does not detect Auto Focus and Auto Deskew options in ABR3000D.

2. When scanning a batch (level II on the film) one frame too many (the first frame of the next batch) was scanned.

3. Manually typing percentage values into the viewer zoom box caused type mismatch errors.

Notes:

1. The full install version of PowerFilm 4.2.15 now asks for additional site code information when starting for the first time.  The 4.2.15 update works as before.


PowerFilm Version 4.2.14 - Release Notes
========================================

Primary Reason for Release - Fixes to 4.2.13 install.

Software Effected - PowerFilm version 4.2.10 and 4.2.13

Availability - 16th September 1998

Fixes:

1. Pressing the TAB key while indexing now moves from index field to index field in a downwards direction.

2. In indexing setup users are no longer able to add an invalid default value for an index field, i.e., if the field type is number and the user enters AAA as the default value, PowerFilm will reject it.

3. Users can now load *.csv files created with unsupported system dates, i.e., Mon 15 Jan 1998 (15 Jan 1999 is supported).  This applies to the image scan date only not dates in index fields.  Note that if the batch is re-saved in *.IDX format, the unsupported date is not written to the IDX file.

4. Users can now load *.IDX files that do not include scan dates.

5. In print and fax dialogs, the printer pick list is no longer corrupted or contains commas.  All printers or fax drivers are available.
 
 	
Notes:

1. This will be the new shipping version of PowerFilm.

2. If your current installation of PowerFilm is version 4.2.13 (Choose About from the Help Menu) please contact InfoCAP Technologies before running this update.



PowerFilm 4.2.13 Release Notes
==============================

Primary Reason for Release - Support for Bell + Howell MRS 60 Controller.

Software Effected - PowerFilm version 4.2.10

Other Enhancements added in this release:

1. Added support for printing multiple copies to the print dialog.
 
2. PowerFilm will now run on the same PC as PowerBook and maintain independent configuration parameters.  PowerFilm should be installed after PowerBook.
 
3. Additional diagnostic information is written to the error log at startup to allow InfoCAP Technologies to diagnose installation problems.


Availability	24th August, 1998

 
Fixes:

1. Indexing now correctly restricts the user to 32 characters if the output type is IDX.
 
2. Date now maintained correctly when moving between *.CSV and *.IDX output.
 
3. Search, Move and Microfilm Control sections of the Film Control Tab no longer accept non-numeric values.
 
4. Batch name prefix no longer accepts illegal characters (alpha/numeric only).
 
5. Each field in the *.CSV output is now in double quotes to allow for indexes or date strings that include commas.

6. Invalid serial numbers no longer accepted in opening serial number and password screen.

Notes:

1. Although MRS 60 support is built in, the option can only be enabled with an authenticated release key.
	
Documentation Updates

1. The PowerFilm Options Dialog, accessible by choosing Options from the File menu, has been modified to facilitate support for the Bell + Howell MRS Controller.


2. The MARS Tab has been renamed to Controller.  Users are now able to define whether they have a Mini MARS II controller or a MRS 60 Controller attached to the ABR3000D.
The PowerFilm MRS 60 Controller Software is a PowerFilm Option.  See the PowerFilm MRS 60 Controller Option Documention for further details on setting up and using PowerFilm with this device.

3. The PowerFilm Print Dialog has been updated to include control of the number of print copies required.